BLMA
|
|
2 ... 4 GHz
|
Model
|
Frequency Range
|
Output Power
PN min W
|
Gain min / typ dB
|
Harmonics 2nd / 3rd dBc
|
Line Power
W
|
Dimensions (H, D) 19"-System
|
Weight
kg
|
BLMA 2040-1
|
2 ... 4 GHz
|
1
|
30 / 32 ?
|
20 / 20
|
75
|
3 HU, 350 mm
|
11
|
BLMA 2040-3
|
2 ... 4 GHz
|
3
|
34.8 / 37 ?
|
20 / 20
|
75
|
3 HU, 350 mm
|
11
|
BLMA 2040-7
|
2 ... 4 GHz
|
7
|
38.5 / 41 ?
|
20 / 20
|
125
|
3 HU, 350 mm
|
12
|
BLMA 2040-20
|
2 ... 4 GHz
|
20
|
43 / 45 ?
|
20 / 20
|
200
|
3 HU, 350 mm
|
15
|
BLMA 2040-35
|
2 ... 4 GHz
|
35
|
45,4 / 48 ?
|
20 / 20
|
400
|
3 HU, 630 mm
|
18
|
BLMA 2040-60
|
2 ... 4 GHz
|
60
|
47.8 / 50 ?
|
20 / 20
|
600
|
3 HU, 630 mm
|
26
|
BLMA 2040-110
|
2 ... 4 GHz
|
110
|
50.4 / 53 ?
|
20 / 20
|
1100
|
3 HU, 630 mm
|
28
|
BLMA 2040-200
|
2 ... 4 GHz
|
200
|
53 / 55 ?
|
20 / 20
|
2500
|
6 HU, 630 mm
|
45
|
BLMA 2040-300
|
2 ... 4 GHz
|
300
|
54.8 / 57 ?
|
20 / 20
|
4000
|
12 HU, 630 mm
|
120
|
BLMA 2040-400
|
2 ... 4 GHz
|
400
|
56 / 58 ?
|
20 / 20
|
5000
|
15 HU, 630 mm
|
150
|
Standard Specifications:
|
Input Power:
|
0 dBm (1 mW) max.
|
Overdrive Protection:
|
up to +10 dBm for no damage
|
Input Impedance:
|
50 Ohm nominal
|
Output Impedance:
|
50 Ohm nominal
|
Input VSWR:
|
<2:1 typ.
|
Load VSWR:
|
2:1 max. for PN -0.5 dB infinite for no damage
|
Spurious (at PN):
|
-50 dBc typ. (excluding harmonics)
|
Class of Operation:
|
A-linear
|
General: |
RF Input: |
N-f (<8 GHz), standard on rear panel SMA-f (8 to 18 GHz), standard on front panel K-f (>18 GHz), standard on front panel |
RF Output: |
N-f (<8 GHz), standard on rear panel SMA-f (8 to 18 GHz), standard on front panel K-f (>18 GHz), standard on front panel
|
Mains Supply: |
Line Power: <1000 W 100 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: 1000 ... 3000 W 200 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: >3000 W 3x 400 V AC ?0% / 47 ... 63 Hz |
Elapsed Time Meter: |
via status display |
Ambient Temperature: |
0 ... +45 癈 |
Storage Temperature: |
-20 ... +85 癈 |
Relative Humidity: |
up to 95% (non-condensing ) |
Operating Altitude: |
up to 2000 m above sea level |
Vibration and Shock: |
MIL-STD-810 F |
Cooling: |
forced air with integral blower, air intake from front air exhaust at rear |
Options: |
A) RF Monitor Outputs |
G) Output Isolator |
B) External Dual Directional Coupler |
H) DC-Supply |
C) IEEE-488.2 GPIB Remote Control |
I) 3x 200 V AC / 60 Hz |
D) Front Panel RF-Connectors |
R) RS-232C Remote Control |
E) Power Indication (digital) |
U) USB Remote Control |
F) Gain Adjustment |
|
|
Specifications are subject to change without notice |
|
|
|
|
我们能为您定制的各种系统的解决方案 |
|
|
|
|