BLWA
|
|
47 ... 1000 MHz
|
Model
|
Frequency Range
|
Output Power
PN min W
|
Gain min / typ dB
|
Harmonics 2nd / 3rd dBc
|
Line Power
W
|
Dimensions (H, D) 19"-System
|
Weight
kg
|
BLWA 0510-1
|
47 ... 1000 MHz
|
1
|
30 / 32 ?
|
20 / 20
|
75
|
3 HU, 350 mm
|
11
|
BLWA 0510-3
|
47 ... 1000 MHz
|
3
|
34.8 / 37 ?
|
20 / 20
|
100
|
3 HU, 350 mm
|
11
|
BLWA 0510-5
|
47 ... 1000 MHz
|
5
|
37 / 39 ?
|
20 / 20
|
150
|
3 HU, 350 mm
|
11
|
BLWA 0510-10
|
47 ... 1000 MHz
|
10
|
40 / 42 ?
|
20 / 20
|
150
|
3 HU, 350 mm
|
13
|
BLWA 0510-30
|
47 ... 1000 MHz
|
30
|
44.8 / 47 ?
|
20 / 20
|
200
|
3 HU, 350 mm
|
13
|
BLWA 0510-50
|
47 ... 1000 MHz
|
50
|
47 / 49 ?
|
20 / 20
|
400
|
4 HU, 550 mm
|
22
|
BLWA 0510-100
|
47 ... 1000 MHz
|
100
|
50 / 52 ?
|
20 / 20
|
900
|
4 HU, 550mm
|
26
|
BLWA 0510-150
|
47 ... 1000 MHz
|
150
|
51.8 / 54 ?
|
20 / 20
|
1500
|
5 HU, 630mm
|
40
|
BLWA 0510-350/160/100D
|
47 ... 1000 MHz
25 ... 100 MHz 100 ... 400 MHz 400 ... 1000 MHz
|
350/160/100
350 160 100
|
55.4 / 58 ? 52 / 54 ? 50 / 52 ?
|
20 / 15 20 / 15 20 / 20
|
1000
|
8 HU, 550 mm
|
60
|
Standard Specifications:
|
Input Power:
|
0 dBm (1 mW) max.
|
Overdrive Protection:
|
up to +10 dBm for no damage
|
Input Impedance:
|
50 Ohm nominal
|
Output Impedance:
|
50 Ohm nominal
|
Input VSWR:
|
<2:1 typ.
|
Load VSWR:
|
2:1 max. for PN -0.5 dB; infinite for no damage
|
Spurious (at PN):
|
-50 dBc typ. (excluding harmonics)
|
Class of Operation:
|
A linear or A-B linear
|
General: |
RF Input: |
N-f; standard on rear panel |
RF Output: |
standard on rear panel N-f (PN up to 1 kW) 7/16-f (PN >1 kW) 13/30-f or 1 5/8" EIA (PN >2 kW) |
Mains Supply: |
Line Power: <1000 W 100 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: 1000 ... 3000 W 200 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: >3000 W 3x 400 V AC ?0% / 47 ... 63 Hz |
Elapsed Time Meter: |
via status display |
Ambient Temperature: |
0 ... +45 癈 |
Storage Temperature: |
-20 ... +85 癈 |
Relative Humidity: |
up to 95% (non-condensing) |
Operating Altitude: |
up to 2000 m above sea level |
Vibration and Shock: |
MIL-STD-810 F |
Cooling: |
forced air with integral blower, air intake from front air exhaust at rear |
Options: |
A) RF Monitor Outputs |
F) Gain Adjustment |
B) External Dual Directional Coupler |
H) DC-Supply |
C) IEEE-488.2 GPIB Remote Control |
I) 3x 200 V AC / 60 Hz |
D) Front Panel RF-Connectors |
R) RS-232C Remote Control |
E) Power Indication (digital) |
U) USB Remote Control |
|
Specifications are subject to change without notice |
|
|
|
|
|