BLWA
|
|
80 ... 400 MHz
|
Model
|
Frequency Range
|
Output Power
PN min W
|
Gain min / typ dB
|
Harmonics 2nd / 3rd dBc
|
Line Power
W
|
Dimensions (H, D) 19"-System
|
Weight
kg
|
BLWA 0840-150
|
80 ... 400 MHz
|
150
|
51.8 / 54 ?
|
20 / 15
|
800
|
4 HU, 550 mm
|
30
|
BLWA 0840-250
|
80 ... 400 MHz
|
250
|
54 / 56 ?
|
20 / 15
|
1600
|
4 HU, 630 mm
|
35
|
BLWA 0840-500
|
80 ... 400 MHz
|
500
|
57 / 59 ?
|
20 / 15
|
3000
|
6 HU, 630 mm
|
55
|
BLWA 0840-750
|
80 ... 400 MHz
|
750
|
58.8 / 61 ?
|
20 / 15
|
4500
|
8 HU, 630 mm
|
120
|
BLWA 0840-1000
|
80 ... 400 MHz
|
1000
|
60 / 62 ?
|
20 / 15
|
8000
|
16 HU, 630 mm
|
180
|
BLWA 0840-1500
|
80 ... 400 MHz
|
1500
|
61.8 / 64 ?
|
20 / 15
|
10000
|
19 HU, 630 mm
|
200
|
BLWA 0840-2000
|
80 ... 400 MHz
|
2000
|
63 / 65 ?
|
20 / 15
|
17000
|
29 HU, 630 mm
|
300
|
BLWA 0840-2500
|
80 ... 400 MHz
|
2500
|
64 / 66 ?
|
20 / 15
|
20000
|
41 HU, 630 mm
|
400
|
BLWA 0840-4000
|
80 ... 400 MHz
|
4000
|
66 / 68 ?
|
20 / 15
|
35000
|
2x32 HU, 630 mm
|
600
|
BLWA 0840-5000
|
80 ... 400 MHz
|
5000
|
67 / 69 ?
|
20 / 15
|
45000
|
2x32 HU, 630 mm
|
800
|
Standard Specifications:
|
Input Power:
|
0 dBm (1 mW) max.
|
Overdrive Protection:
|
up to +10 dBm for no damage
|
Input Impedance:
|
50 Ohm nominal
|
Output Impedance:
|
50 Ohm nominal
|
Input VSWR:
|
<2:1 typ.
|
Load VSWR:
|
2:1 max. for PN -0.5 dB; infinite for no damage
|
Spurious (at PN):
|
-50 dBc typ. (excluding harmonics)
|
Class of Operation:
|
A linear or A-B linear
|
General: |
RF Input: |
N-f; standard on rear panel |
RF Output: |
standard on rear panel N-f (PN up to 1 kW) 7/16-f (PN >1 kW) 13/30-f or 1 5/8" EIA (PN >2 kW) |
Mains Supply: |
Line Power: <1000 W 100 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: 1000 ... 3000 W 200 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: >3000 W 3x 400 V AC ?0% / 47 ... 63 Hz |
Elapsed Time Meter: |
via status display |
Ambient Temperature: |
0 ... +45 癈 |
Storage Temperature: |
-20 ... +85 癈 |
Relative Humidity: |
up to 95% (non-condensing) |
Operating Altitude: |
up to 2000 m above sea level |
Vibration and Shock: |
MIL-STD-810 F |
Cooling: |
forced air with integral blower, air intake from front air exhaust at rear |
Options: |
A) RF Monitor Outputs |
F) Gain Adjustment |
B) External Dual Directional Coupler |
H) DC-Supply |
C) IEEE-488.2 GPIB Remote Control |
I) 3x 200 V AC / 60 Hz |
D) Front Panel RF-Connectors |
R) RS-232C Remote Control |
E) Power Indication (digital) |
U) USB Remote Control |
|
Specifications are subject to change without notice |
|
|
|
我们能为您定制的各种系统的解决方案 |
|
|
|
|