BLWA
|
|
| 80 ... 4000 MHz
|
| Model
|
Frequency Range
|
Output Power
PN min W
|
Gain min / typ dB
|
Harmonics 2nd / 3rd dBc
|
Line Power
W
|
Dimensions (H, D) 19"-System
|
Weight
kg
|
| BLWA 084O-160/100/60/30D
|
80 ... 4000 MHz
80 ... 400 MHz 400 ... 1000 MHz 1 ... 2 GHz 2 ... 4 GHz
|
160/100/60/30
160 100 60 30
|
54 / 56 ? 50 / 52 ? 47.8 / 50 ? 44.8 / 47 ?
|
20 / 15 20 / 20 20 / 20 20 / 20
|
1200
|
6 HU, 630 mm
|
65
|
| Standard Specifications:
|
| Input Power:
|
0 dBm (1 mW) max.
|
| Overdrive Protection:
|
up to +10 dBm for no damage
|
| Input Impedance:
|
50 Ohm nominal
|
| Output Impedance:
|
50 Ohm nominal
|
| Input VSWR:
|
<2:1 typ.
|
| Load VSWR:
|
2:1 max. for PN -0.5 dB; infinite for no damage
|
| Spurious (at PN):
|
-50 dBc typ. (excluding harmonics)
|
| Class of Operation:
|
A linear or A-B linear
|
|
General: |
| RF Input: |
N-f; standard on rear panel |
| RF Output: |
standard on rear panel N-f (PN up to 1 kW) 7/16-f (PN >1 kW) 13/30-f or 1 5/8" EIA (PN >2 kW) |
| Mains Supply: |
Line Power: <1000 W 100 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: 1000 ... 3000 W 200 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: >3000 W 3x 400 V AC ?0% / 47 ... 63 Hz |
| Elapsed Time Meter: |
via status display |
| Ambient Temperature: |
0 ... +45 癈 |
| Storage Temperature: |
-20 ... +85 癈 |
| Relative Humidity: |
up to 95% (non-condensing) |
| Operating Altitude: |
up to 2000 m above sea level |
| Vibration and Shock: |
MIL-STD-810 F |
| Cooling: |
forced air with integral blower, air intake from front air exhaust at rear |
| Options: |
| A) RF Monitor Outputs |
F) Gain Adjustment |
| B) External Dual Directional Coupler |
H) DC-Supply |
| C) IEEE-488.2 GPIB Remote Control |
I) 3x 200 V AC / 60 Hz |
| D) Front Panel RF-Connectors |
R) RS-232C Remote Control |
| E) Power Indication (digital) |
U) USB Remote Control |
| |
| Specifications are subject to change without notice |
| |
|
|
|