BPA / TWAP
|
|
1,15 ... 1,45 GHz
|
Model
|
Frequency Range
|
Output Power
PP min W
|
Gain typ dB
|
Harmonics 2nd / 3rd dBc
|
Line Power
W
|
Dimensions (H, D) 19"-System
|
Weight
kg
|
BPA 1114-900
|
1,15 ... 1,45 GHz
|
900
|
59 ?.5
|
30 / 30
|
500
|
3 HU, 630 mm
|
22
|
Standard Specifications:
|
Input Power:
|
0 dBm (1 mW) max.
|
Overdrive Protection:
|
up to +10 dBm for no damage
|
Input Impedance:
|
50 Ohm nominal
|
Output Impedance:
|
50 Ohm nominal
|
Input VSWR:
|
<2:1 typ.
|
Load VSWR:
|
2:1 max. for Ppk-0.5 dB; infinite (with option G)
|
Puls Width:
|
120 祍
|
Duty Cycle:
|
10%
|
Risetime / Falltime:
|
<200 ns
|
Pulse Droop:
|
1.0 dB
|
Spurious:
|
-50 dBc typ. (excluding harmonics)
|
Class of Operation:
|
C
|
General: |
RF Input: |
N-f; standard on rear panel |
RF Output: |
N-f; standard on rear panel |
Ambient Temperature: |
0 ... +45 癈 |
Mains Supply: |
Line Power: <1000 W 100 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: 1000 ... 3000 W 200 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: >3000 W 3x 400 V AC ?0% / 47 ... 63 Hz |
Storage Temperature: |
-20 ... +85 癈 |
Relative Humidity: |
up to 95% (non-condensing) |
Cooling: |
forced air with integral blower, air intake from front air exhaust at rear |
Vibration and Shock: |
MIL-STD-810 F |
Operating Altitude: |
up to 2000 m above sea level |
Options: |
A) RF Monitor Outputs |
H) DC-Supply |
B) External Dual Directional Coupler |
N) Harmonic Filter |
D) Front Panel RF-Connectors |
I) 3x 200 V AC / 60 Hz |
C) IEEE-488.2 GPIB Remote Control |
R) RS-232C Remote Control |
E) Power Indication (digital) |
S) Gate Input |
G) Output Isolator |
U) USB Remote Control |
|
Specifications are subject to change without notice |
|
|
|
|