TWAL
|
|
1 ... 2,5 GHz
|
Model
|
Frequency Range
|
Output Power
PN min W
|
Gain min / typ dB
|
Harmonics 2nd / 3rd dBc
|
Line Power
W
|
Dimensions (H,D) 19''-System
|
Weight
kg
|
TWAL 0103-250
|
1 ... 2,5 GHz
|
250
|
54 / 62 ?.5
|
4 / 12
|
3000
|
5 HU, 660 mm
|
48
|
TWAL 0103-320
|
1 ... 2,5 GHz
|
320
|
55 / 63 ?.5
|
3 / 10
|
3500
|
5 HU, 660 mm
|
48
|
TWAL 0103-500
|
1 ... 2,5 GHz
|
500
|
54 / 62 ?.5
|
2 / 10
|
4000
|
14 HU, 660 mm
|
140
|
TWAL 0103-1000
|
1 ... 2,5 GHz
|
1000
|
50 / 60 ?0
|
8 / 20
|
12000
|
32 HU, 800 mm
|
340
|
Standard Specifications:
|
Input Power
|
0 dBm (1 mW) max.
|
Overdrive Protection:
|
up to +10 dBm for no damage
|
Input Impedance:
|
50 Ohm nominal
|
Output Impedance:
|
50 Ohm nominal
|
Input VSWR:
|
<2:1 typ.
|
Load VSWR:
|
2:1 max. for PN -0.5 dB infinite for no damage
|
Spurious (at PN):
|
-50 dBc typ.(excluding harmonics)
|
Noise Figure:
|
20 dB max.
|
Class of Operation:
|
A-linear
|
General: |
RF Input: |
1 ... 18 GHz: N-f; standard on rear panel 18 ... 40 GHz: k-f; standard on rear panel
|
RF Output (1 kW): |
standard on rear panel 1 ... 10 GHz: N-f 8 ... 18 GHz: WRD 750 18 ... 26.5 GHz: WR 42 26.5 ... 40 GHz: WR 28 |
RF Output (>1 kW): |
standard on rear panel 1 ... 8 GHz: 7/16 8 ... 18 GHz: WRD 750 |
Gain Adjustment: |
via status display (<4 GHz) or via thumbwheel (>4 GHz) |
RF Monitor Output |
-50 dB forward |
Mains Supply: |
200 ... 264 V AC / 47 ... 63 Hz |
Power Meter: |
via status display |
Elapsed Time Meter: |
via status display |
Ambient Temperature: |
0 ... +40 癈 |
Storage Temperature: |
-20 ... +85 癈 |
Relative Humidity: |
up to 95% (non-condensing) |
Operating Altitude: |
up to 2000 m above sea level |
Vibration and Shock: |
normal laboratory environment |
Cooling: |
forced air with integral blower, air intake and exhaust at rear |
Options: |
A) Reverse Monitor |
G) Output Isolator |
B) External Dual Directional Coupler |
M) 115 V AC / 47 ... 63 Hz |
C) IEEE-488.2 GPIB Remote Control |
N) Harmonic Filter |
|
R) RS-232C Remote Control |
|
U) USB Remote Control |
(1) |
Combiner is limiting the actual frequency range |
|
Specifications are subject to change without notice |
|
|
|
|
我们能为您定制的各种系统的解决方案 |
|
|
|
|