TWAL
|
|
| 4 ... 18 GHz
|
| Model
|
Frequency Range
|
Output Power
PN / W
|
Gain min / typ dB
|
Harmonics 2nd / 3rd dBc
|
Line Power
W
|
Dimensions (H,D) 19''-System
|
Weight
kg
|
| TWAL 0418-30E
|
4 ... 18 GHz
4.2 ... 4.5 GHz 4.5 ... 6 GHz 6 ... 18 GHz
|
(30)
20 30 70
|
45 / 55 ?0
|
+3 / -10
|
600
|
3 HU, 550 mm
|
20
|
| TWAL 0418-20
|
4 ... 18 GHz
|
20
|
43 / 51 ?.5
|
0 / 5
|
600
|
3 HU, 550 mm
|
20
|
| Standard Specifications:
|
| Input Power
|
0 dBm (1 mW) max.
|
| Overdrive Protection:
|
up to +10 dBm for no damage
|
| Input Impedance:
|
50 Ohm nominal
|
| Output Impedance:
|
50 Ohm nominal
|
| Input VSWR:
|
<2:1 typ.
|
| Load VSWR:
|
2:1 max. for PN -0.5 dB infinite for no damage
|
| Spurious (at PN):
|
-50 dBc typ.(excluding harmonics)
|
| Noise Figure:
|
20 dB max.
|
| Class of Operation:
|
A-linear
|
|
General: |
| RF Input: |
N-f; standard on rear panel |
| RF Output: |
N-f; standard on rear panel |
| Mains Supply: |
200 ... 264 V AC / 47 ... 63 Hz |
| Elapsed Time Meter: |
via status display |
| Ambient Temperature: |
0 ... +40 癈 |
| Storage Temperature: |
-20 ... +85 癈 |
| Relative Humidity: |
up to 95% (non-condensing) |
| Operating Altitude: |
up to 2000 m above sea level |
| Vibration and Shock: |
normal laboratory environment |
| Cooling: |
forced air with integral blower, air intake and exhaust at rear |
| Options: |
| A) RF Monitor Outputs |
G) Output Isolator |
| B) External Dual Directional Coupler |
M) 115 V AC / 47 ... 63 Hz |
| C) IEEE-488.2 GPIB Remote Control |
N) Harmonic Filter |
| D) Front Panel RF Connectors |
R) RS-232C Remote Control |
| E) Power Indication (digital) |
U) USB Remote Control |
| F) Gain Adjustment |
|
| |
| Specifications are subject to change without notice |
| |
|
|
|