General: |
| RF Input: |
1 ... 18 GHz: N-f; standard on rear panel 18 ... 40 GHz: k-f; standard on rear panel
|
| RF Output (1 kW): |
standard on rear panel 1 ... 10 GHz: N-f 8 ... 18 GHz: WRD 750 18 ... 26.5 GHz: WR 42 26.5 ... 40 GHz: WR 28 |
| RF Output (>1 kW): |
standard on rear panel 1 ... 8 GHz: 7/16 8 ... 18 GHz: WRD 750 |
| Gain Adjustment: |
via status display (<4 GHz) or via thumbwheel (>4 GHz) |
| RF Monitor Output |
-50 dB forward |
| Mains Supply: |
200 ... 264 V AC / 47 ... 63 Hz |
| Power Meter: |
via status display |
| Elapsed Time Meter: |
via status display |
| Ambient Temperature: |
0 ... +40 癈 |
| Storage Temperature: |
-20 ... +85 癈 |
| Relative Humidity: |
up to 95% (non-condensing) |
| Operating Altitude: |
up to 2000 m above sea level |
| Vibration and Shock: |
normal laboratory environment |
| Cooling: |
forced air with integral blower, air intake and exhaust at rear |